- Available with spring on request → prevents return flow even with very little pressure drop → any installation position
- Housing made of PP, PVDF and PFA → high media resistance
- Valve ring with O-ring → maximum tightness
- As standard with seam-less G or NPT female thread → various connection options
- Input also available with seam-less G or NPT male thread
Wherever medium must be prevented from flowing back in systems, or equipment is to be protected against medium blow back, check valves are used. Two types are available:
The check valve without a spring is primarily used for the protection of fittings against blow-back from a system. These valves have a low opening pressure.
The check valve with a spring on the other hand prevents medium flowing back on a pressure drop. In this case the spring automatically closes the valve.